Tests any boiler up to & over 5MW / 50 mbar draught with high suction pump
Measures CO to 100,000ppm / 10%, HC to 5000ppm & CO2 to 20%
Option to measure NO, NO2, SO2 & H2S
Large graphic colour display & keypad
Wirelessly connects optional KANE LINK devices to measure flow & return, air flow & air quality
Tests air conditioning & refrigeration system superheat & subcool - wireless KANE LINK devices available soon
MCERTS (pending) tests with optional KANE GCU Gas Chiller Unit
Backed by KANE CARE 10 year warranty - We promise to never let you down or your money back
Applications
Install, commission & service any heating & hot water system using any fossil, biomass & HVO fuel
Optional environmental sensors test to local regulations
Accurate NO2 & SO2 measurements with optional KANE-GCU gas conditioning unit
Safety checks - CO in rooms & around appliances
Combustion performance & efficiency tests
Flue draught & gas pressure / system tightness tests
Flow & return, air flow & air quality tests
Air conditioning & refrigeration superheat & subcool tests
Backed by KANE CARE - We promise to never let you down or your money back
Measures
O2 to 21% ppm to 0.01% resolution
CO to 10,000ppm H2compensated & 100,000ppm / 10%
CO2 to 21% with 40% over range
HC to 5,000ppm
Temperature - inlet / flue gas / differential / ambient / flow & return
High accuracy differential pressure meter +/- 160mbar
Velocity measurement to 30m/s with optional pitot tube
NO to 5,000ppm - option
NO2 to 1,000ppm - option
SO2 0-5,000ppm - option
H2S to 200ppm - option
Calculates
CO/CO2 ratio
Combustion efficiency,
Excess air / Lambda
NOx - if NO fitted
Superheat & Subcool - with optional KANE LINK devices available soon
Fuel Types
Natural Gas x2 & Town Gas
LPG, Biogas & Kinsale Gas
Butane, Propane & Gascor
Light oil & Heavy oil
Coke, Coal & Anthracite
Up to 5 user fuels
Box Contents
PTFE Lined Combustion Probe
Battery Charger
Rucksack / Backpack
Protective Handset Pouch